Thhn Thwn Thw-Tw Copper Nylon Jacket PVC Building Electric Wire

Model NO.: Thhn/Thw/Thwn
Certification: ISO, CCC, CE
Model: Thhn/Thw/Thwn
Brand: Hongda
Color: Red, Black, Yellow, Green, Blue and So on.
Trademark: Hongda
Transport Package: Flexible Package or Drum
Origin: Zhengzhou China
HS Code: 8544492100
Model NO.: Thhn/Thw/Thwn
Certification: ISO, CCC, CE
Model: Thhn/Thw/Thwn
Brand: Hongda
Color: Red, Black, Yellow, Green, Blue and So on.
Trademark: Hongda
Transport Package: Flexible Package or Drum
Origin: Zhengzhou China
HS Code: 8544492100

THHN THWN THW-TW Copper Nylon Jacket PVC Building Electric Wire

APPLICATION: 
General purpose wiring for lighting and power - residential, 
Commercial, industrial buildings in accordance with the National Electrical 
Code, maximum conductor temperature of 75° C in wet or dry locations, 
For circuits not exceeding 600 volts 

STANDARDS: 
1. Listed by UL as Type THW per Standard 83. 
2. All sizes carry the VW-1 flame test designation. 
3. Listed by UL as Oil Resistant I. 
4. Listed by UL as Sunlight Resistant (250 kcmil and larger, black only) 
5.250 kcmil and larger pass UL and IEEE-383 ribbon burner flame test 
And are listed For CT Use. 
6. Conforms to Federal Specification J-C-30B. 

THHN-THWN-THW-TW (Nylon Jacket PVC Building Electric Wire) meets or exceeds the requirements of all international standards like ASTM,IEC,DIN,BS,AS,CSA,NFC,SS,etc. in addition, we also accept OEM service to meet your special request.

Applications:

1.Type THHN / THWN / THW / TW Cable is intended for general purpose applications as defined by the National Electrical Code (NEC)Type THHN-THWN-2 is permitted for new construction or rewiring for 60 volt applications. Applications requiring Type THHN or THWN.

a. THHN wire: It indicates a single or stranded conductor having flame-retardant and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent material. The wire is rated 90°C dry only.THHN cable may also be used for wiring of machine tools, control circuits or on certain appliances.

b. THWN wire: It Indicates a single conductor having flame-retardant, moisture and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent material. The wire is rated 75°C wet or dry. THWN cable is typically used for installation in conduit, machine tools, controlled circuits, or other general purpose wiring.

c.THW wire- Indicates a single conductor having flame-retardant, moisture and heat-resistant thermoplastic insulation. The wire is rated 75°C wet or dry.THW cable and wires are used generally in building wiring, feeder and branch circuits, and internal secondary industrial distribution.

d.TW wire- Indicates a single conductor having flame-retardant, moisture-resistant thermoplastic insulation. The wire is rated 60°C wet or dry.TW cable and wires are used generally in building wiring, feeder and branch circuits, and internal secondary industrial distribution.
 

2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.

Features:
1) Nylon outer jacket PVC electric wire for easy pulling. VW-1 rated 14 AWG - 8 AWG. All sizes are rated gasoline and oil-resistant II.
2) Jacket: Nylon jacket is provided to protect PVC insulation against abrasions and scratches while pulling through conduits. It is also resistant to oil , gasoline and chemicals.

Building Wire Construction:
Insulation: PVC (Poly Vinyl Chloride) with Secondary Nylon Jacket
Conductor: Annealed solid or stranded copper wires (copper or CCA)
Voltage Rating: 600 Volts.

Standard:
THHN or THWN-2* or MTW wire (also AWM) meets or exceeds all applicable ASTM specifications, UL Standard 83, UL Standard 1063 (MTW), Federal Specification A-A-59544, and requirements of the National Electrical Code.

Parameter of THHN Wire

specification: 

 

 

Part No.

 

Conductor

Insulation

Jacket

 

 

Max

Dia-

meter

(mm)

 

 

 

Ref.W

 

(kg/km)

Type

Size

(AWG)

Construction

(No./mm)

 

Dia-

Meter

(mm)

Nominal

Thickness

(mm)

 

Nominal

Diameter

(mm)

 

Minimum Thickness

At any point

(mm)

 

Nominal

Diameter

(mm)

THHN-14B

 

 

Stranded

Conductor

 

14

7/0.62

1.86

0.38

2.66

0.10

2.90

3.3

25

THHN-14B1

14

19/0.38

1.90

0.38

2.70

0.10

2.94

3.4

25

THHN-12B

12

7/0.78

2.34

0.38

3.14

0.10

3.38

3.8

38

THHN-12B1

12

19/0.47

2.35

0.38

3.15

0.10

3.39

3.8

38

THHN-10B

10

7/0.98

2.94

0.51

4.00

0.10

4.24

4.8

59

THHN-10B1

10

19/0.60

3.00

0.51

4.06

0.10

4.30

4.8

59

THHN-8B

8

7/1.23

3.69

0.76

5.25

0.13

5.55

6.2

97

THHN-8B1

8

19/0.75

3.75

0.76

5.31

0.13

5.61

6.3

96

THHN-6B

6

7/1.56

4.68

0.76

6.24

0.13

6.54

7.3

147

THHN-6B1

6

19/0.95

4.77

0.76

6.33

0.13

6.63

7.4

146

THHN-4B

4

7/1.96

5.88

0.76

7.44

0.13

7.74

8.7

135

THHN-4B1

4

19/1.19

5.95

0.76

7.51

0.13

7.81

8.7

135

THHN-3B

3

7/2.20

6.60

1.02

8.68

0.15

9.02

10.0

292

THHN-3B1

3

19/1.33

6.65

1.02

8.73

0.15

9.07

10.0

291

THHN-2B

2

7/2.47

7.41

1.02

9.49

0.15

9.83

11.0

361

THHN-2B1

2

19/1.50

7.50

1.02

9.58

0.15

9.92

11.0

361

THHN-1B

1

19/1.68

8.40

1.02

10.48

0.18

10.88

12.1

457

THHN-1/0B

1/0

19/1.89

9.45

1.27

12.03

0.18

12.43

13.8

585

THHN-2/0B

2/0

19/2.12

10.60

1.27

13.18

0.18

13.58

15.1

724

THHN-3/0B

3/0

19/2.38

11.90

1.27

14.48

0.18

14.88

16.5

900

THHN-4/0B

4/0

19/2.67

13.35

1.27

15.93

0.18

16.33

18.1

1118

 

 

THHN-14A

 

Solid

Conductor

14

1/1.63

1.63

0.38

2.43

0.10

2.67

3.1

22

THHN-12A

12

1/2.05

2.05

0.38

2.85

0.10

3.09

3.5

36

THHN-10A

10

1/2.59

2.59

0.51

3.65

0.10

3.89

4.4

57

THHN-8A

8

1/3.26

3.26

0.76

4.82

0.13

5.12

5.7

94

Contact Us
If you have more questions, please contact with Ellen Zhang.
Ellen Zhang
Phone: 86 150 0380 6907
Skype/Whatsapp:  86 150 0380 6907
Wechat: 150 0380 6907
QQ: 812 747 988
E-mail: ellen@hongdacable.com

Factory

Thhn Thwn Thw-Tw Copper Nylon Jacket PVC Building Electric Wire

 Henan Hongda Cable Co., Ltd. located in No. 3, Changping Road, ZhanDian District, Jiaozuo, Wuzhi. Our factroy established in March of 2004. Our owns registered capital of RMB Fifty-one million six hundred and eighty thousand. Hongda Cable
covers an area of 100,000 square meters, including 50,000 square meters of building area. We have more than 120 staff members and professional workers. our fixed assets of 90,000,000. We can provide more than 100 varieties, tens of thousands of specifications of wire and cable, with 10000 km annual production capacity
     Henan Hongda Cable Co. Ltd. is the original Zhengzhou Hongda Cable Co. Ltd. established enterprise expansion. The company is committed to system R&D, design, manufacturing, marketing and service of cable products,We mainly aim at managing cross-linking XLPE insulated power cables, PVC insulated power cables, plastic insulated control cables, insulated overhead cables, and stranded aluminum and ACSR. At present, the cables' biggest cross area is 800 square meters with a maximum electric power of 35KV. The company has more than 300 (sets) domestic and oversea-leading production and testing equipment.

Packing and Transportation

Thhn Thwn Thw-Tw Copper Nylon Jacket PVC Building Electric Wire


We provide you with the best product packaging design services, thereby allowing you to save more shipping charges

Certificate

Thhn Thwn Thw-Tw Copper Nylon Jacket PVC Building Electric Wire


FAQ
   Q: Are you the factory or the trading company?

    A: We are the factory. 
   Q: How long is your guarantee Period?
    A: We uaually offer 1 year guarantee for our general products.
   Q: How can I get the samples?
    A: We can make the sample order. And usually we will charge for it. 
        But the samples fee will be return to you when you make the bulk order.
   Q: Where is your factory? How can we visit your factory?
    A: Our factory located in Zhengzhou city, Henan Province. You could reach here by train and by air.
        We can pick you up in the airport and the railway station.
   Q; What is your MOQ?
    A: It`s base on the cable type or wire type. Please contact me. We will let you know.
 

THHN THWN THW-TW Copper Nylon Jacket PVC Building Electric Wire

APPLICATION: 
General purpose wiring for lighting and power - residential, 
Commercial, industrial buildings in accordance with the National Electrical 
Code, maximum conductor temperature of 75° C in wet or dry locations, 
For circuits not exceeding 600 volts 

STANDARDS: 
1. Listed by UL as Type THW per Standard 83. 
2. All sizes carry the VW-1 flame test designation. 
3. Listed by UL as Oil Resistant I. 
4. Listed by UL as Sunlight Resistant (250 kcmil and larger, black only) 
5.250 kcmil and larger pass UL and IEEE-383 ribbon burner flame test 
And are listed For CT Use. 
6. Conforms to Federal Specification J-C-30B. 

THHN-THWN-THW-TW (Nylon Jacket PVC Building Electric Wire) meets or exceeds the requirements of all international standards like ASTM,IEC,DIN,BS,AS,CSA,NFC,SS,etc. in addition, we also accept OEM service to meet your special request.

Applications:

1.Type THHN / THWN / THW / TW Cable is intended for general purpose applications as defined by the National Electrical Code (NEC)Type THHN-THWN-2 is permitted for new construction or rewiring for 60 volt applications. Applications requiring Type THHN or THWN.

a. THHN wire: It indicates a single or stranded conductor having flame-retardant and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent material. The wire is rated 90°C dry only.THHN cable may also be used for wiring of machine tools, control circuits or on certain appliances.

b. THWN wire: It Indicates a single conductor having flame-retardant, moisture and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent material. The wire is rated 75°C wet or dry. THWN cable is typically used for installation in conduit, machine tools, controlled circuits, or other general purpose wiring.

c.THW wire- Indicates a single conductor having flame-retardant, moisture and heat-resistant thermoplastic insulation. The wire is rated 75°C wet or dry.THW cable and wires are used generally in building wiring, feeder and branch circuits, and internal secondary industrial distribution.

d.TW wire- Indicates a single conductor having flame-retardant, moisture-resistant thermoplastic insulation. The wire is rated 60°C wet or dry.TW cable and wires are used generally in building wiring, feeder and branch circuits, and internal secondary industrial distribution.
 

2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.

Features:
1) Nylon outer jacket PVC electric wire for easy pulling. VW-1 rated 14 AWG - 8 AWG. All sizes are rated gasoline and oil-resistant II.
2) Jacket: Nylon jacket is provided to protect PVC insulation against abrasions and scratches while pulling through conduits. It is also resistant to oil , gasoline and chemicals.

Building Wire Construction:
Insulation: PVC (Poly Vinyl Chloride) with Secondary Nylon Jacket
Conductor: Annealed solid or stranded copper wires (copper or CCA)
Voltage Rating: 600 Volts.

Standard:
THHN or THWN-2* or MTW wire (also AWM) meets or exceeds all applicable ASTM specifications, UL Standard 83, UL Standard 1063 (MTW), Federal Specification A-A-59544, and requirements of the National Electrical Code.

Parameter of THHN Wire

specification: 

 

 

Part No.

 

Conductor

Insulation

Jacket

 

 

Max

Dia-

meter

(mm)

 

 

 

Ref.W

 

(kg/km)

Type

Size

(AWG)

Construction

(No./mm)

 

Dia-

Meter

(mm)

Nominal

Thickness

(mm)

 

Nominal

Diameter

(mm)

 

Minimum Thickness

At any point

(mm)

 

Nominal

Diameter

(mm)

THHN-14B

 

 

Stranded

Conductor

 

14

7/0.62

1.86

0.38

2.66

0.10

2.90

3.3

25

THHN-14B1

14

19/0.38

1.90

0.38

2.70

0.10

2.94

3.4

25

THHN-12B

12

7/0.78

2.34

0.38

3.14

0.10

3.38

3.8

38

THHN-12B1

12

19/0.47

2.35

0.38

3.15

0.10

3.39

3.8

38

THHN-10B

10

7/0.98

2.94

0.51

4.00

0.10

4.24

4.8

59

THHN-10B1

10

19/0.60

3.00

0.51

4.06

0.10

4.30

4.8

59

THHN-8B

8

7/1.23

3.69

0.76

5.25

0.13

5.55

6.2

97

THHN-8B1

8

19/0.75

3.75

0.76

5.31

0.13

5.61

6.3

96

THHN-6B

6

7/1.56

4.68

0.76

6.24

0.13

6.54

7.3

147

THHN-6B1

6

19/0.95

4.77

0.76

6.33

0.13

6.63

7.4

146

THHN-4B

4

7/1.96

5.88

0.76

7.44

0.13

7.74

8.7

135

THHN-4B1

4

19/1.19

5.95

0.76

7.51

0.13

7.81

8.7

135

THHN-3B

3

7/2.20

6.60

1.02

8.68

0.15

9.02

10.0

292

THHN-3B1

3

19/1.33

6.65

1.02

8.73

0.15

9.07

10.0

291

THHN-2B

2

7/2.47

7.41

1.02

9.49

0.15

9.83

11.0

361

THHN-2B1

2

19/1.50

7.50

1.02

9.58

0.15

9.92

11.0

361

THHN-1B

1

19/1.68

8.40

1.02

10.48

0.18

10.88

12.1

457

THHN-1/0B

1/0

19/1.89

9.45

1.27

12.03

0.18

12.43

13.8

585

THHN-2/0B

2/0

19/2.12

10.60

1.27

13.18

0.18

13.58

15.1

724

THHN-3/0B

3/0

19/2.38

11.90

1.27

14.48

0.18

14.88

16.5

900

THHN-4/0B

4/0

19/2.67

13.35

1.27

15.93

0.18

16.33

18.1

1118

 

 

THHN-14A

 

Solid

Conductor

14

1/1.63

1.63

0.38

2.43

0.10

2.67

3.1

22

THHN-12A

12

1/2.05

2.05

0.38

2.85

0.10

3.09

3.5

36

THHN-10A

10

1/2.59

2.59

0.51

3.65

0.10

3.89

4.4

57

THHN-8A

8

1/3.26

3.26

0.76

4.82

0.13

5.12

5.7

94

Contact Us
If you have more questions, please contact with Ellen Zhang.
Ellen Zhang
Phone: 86 150 0380 6907
Skype/Whatsapp:  86 150 0380 6907
Wechat: 150 0380 6907
QQ: 812 747 988
E-mail: ellen@hongdacable.com

Factory

Thhn Thwn Thw-Tw Copper Nylon Jacket PVC Building Electric Wire

 Henan Hongda Cable Co., Ltd. located in No. 3, Changping Road, ZhanDian District, Jiaozuo, Wuzhi. Our factroy established in March of 2004. Our owns registered capital of RMB Fifty-one million six hundred and eighty thousand. Hongda Cable
covers an area of 100,000 square meters, including 50,000 square meters of building area. We have more than 120 staff members and professional workers. our fixed assets of 90,000,000. We can provide more than 100 varieties, tens of thousands of specifications of wire and cable, with 10000 km annual production capacity
     Henan Hongda Cable Co. Ltd. is the original Zhengzhou Hongda Cable Co. Ltd. established enterprise expansion. The company is committed to system R&D, design, manufacturing, marketing and service of cable products,We mainly aim at managing cross-linking XLPE insulated power cables, PVC insulated power cables, plastic insulated control cables, insulated overhead cables, and stranded aluminum and ACSR. At present, the cables' biggest cross area is 800 square meters with a maximum electric power of 35KV. The company has more than 300 (sets) domestic and oversea-leading production and testing equipment.

Packing and Transportation

Thhn Thwn Thw-Tw Copper Nylon Jacket PVC Building Electric Wire


We provide you with the best product packaging design services, thereby allowing you to save more shipping charges

Certificate

Thhn Thwn Thw-Tw Copper Nylon Jacket PVC Building Electric Wire


FAQ
   Q: Are you the factory or the trading company?

    A: We are the factory. 
   Q: How long is your guarantee Period?
    A: We uaually offer 1 year guarantee for our general products.
   Q: How can I get the samples?
    A: We can make the sample order. And usually we will charge for it. 
        But the samples fee will be return to you when you make the bulk order.
   Q: Where is your factory? How can we visit your factory?
    A: Our factory located in Zhengzhou city, Henan Province. You could reach here by train and by air.
        We can pick you up in the airport and the railway station.
   Q; What is your MOQ?
    A: It`s base on the cable type or wire type. Please contact me. We will let you know.
 

IC Logic

Ic Logic,Logic Counters Dividers,Logic Fifos Memory,Logic Buffers Drivers Receivers Transceivers

Shenzhen Kaixuanye Technology Co., Ltd. , https://www.iconlinekxys.com