Model NO.: XR60CX XR70CX
-
Sensing Type: Resistive
-
Output Signal Type: Digital Type
-
Material: Plastic
-
IP Rating: IP20
-
Customized: Non-Customized
-
Measurement Object: Cold Storage, Cold Storage
-
The Size of Hole: 71*29mm
-
Transport Package: Carton Box
-
Origin: Italy
-
Installation Type: Embedded
-
Contact: Contact
-
Production Process: Normal Wirewound
-
Measuring Medium: Temperature
-
Certification: CE
-
Control Mode: Intelligent Temperature Control Regulator
-
Temperature Range: - 50 to + 150 ºC
-
Trademark: Dixell
-
Specification: CE SGS
-
HS Code: 8414301000
Dixell Prime CX Temperature Controller XR60CX XR70CXDixell Controller:XR60CX XR70CXDIGITAL CONTROLLER WITH "OFF CYCLE" DEFROST
Generals
Power supply: 110, 230Vac
Probe inputs
Thermostat: NTC
Digital inputs
Alarm, start defrost, AUX, door switch, pressure switch: Configurable
Relay outputs
Compressor: 8A, 20A optional
Other
Hot Key: Present
Buzzer: Optional (available only with 8A compr. Relay)
Â
The new PRIME series in CX format, is an innovative range of products that Dixell has introduced to the market for both heating and L.T., N.T. refrigeration. The CX family (32x74mm) has new functions plus an innovative and attractive design. The revolutionary introduction of 6 keys allows the user direct access to all main functions rapidly and intuitively, while the display with illuminated icons allows an instant view of the machine's status. All the instruments in CX format incorporate the latest know how and technology, both in software and hardware to ensure the highest standards of performance. Easy and intuitive installation 9 - 40Vdc power supply for refrigerated trucks (for models with 8A compressor) Energy saving cycles triggered via a digital input; for example, it is possible to work at a set point that is different from the normal one in order to, for instance, accumulate cold when electric power is cheaper Continuous cycle with dedicated set; it allows the machine to work during rapid cooling cycles to achieve the right product temperature Regulation stop by auxiliary probe (beer dispenser applications); it is possible to supervise the tube temperature, stopping the compressor when the temperature becomes too low, and restarting when the correct values have been restored Regulation re-start with door switch alarm Max and Min temperature or HACCP function Digital input configurable as probe Virtual probe for air on / air off application; used in multideck applications where it is important to regulate temperature using the average of 2 temperatures Dual thermostat function; is available, on demand, in applications such as white or red wine rooms where it is necessary to maintain 2 different temperatures Condenser temperature management to prevent critical situations in the system TTL serial connection for monitoring systems (using XJ485CX) Connection for remote display X-REP (excludes TTL) |
|
 Â
Controllers  for Medium and Low Temperature Â
XR60CXÂ |
Controller for MT and LT ventilated applications with dual humidity function on demand, this allows the user to activate or deactivate ventilation directly through keys, in order to regulate the humidity depending on the kind of product (ideal for pastry applications) |
XR64CXÂ Â Â |
Controller for MT and LT ventilated applications with twin evaporators; normal regulation restarts only when both evaporators have reached defrost termination temperature |
XR70CXÂ |
Controller for MT and LT ventilated applications, with auxiliary relay and with dual humidity function on demand, this allows the user to activate or deactivate ventilation directly through keys, in order to regulate the humidity depending on the kind of product (ideal for pastry applications) |
XR71CX |
Controller for MT and LT ventilated applications with anti-sweat heater management; created for applications that utilize heating elements such as anti-mist or anti-freeze heaters on doors (heater elements can be actived by pushing a key or through a dedicated probe) |
XR72CXÂ |
Controller for MT and LT ventilated applications with dual compressor management |
XR75CX |
Controller for MT and LT ventilated applications with auxiliary relay, dual humidity function and RS485 |
XR77CX |
Controller for MT and LT ventilated applications with Real time clock with RS485 |
  |
|
  Â
FEATURES |
 XR60CX |
XR64CX |
 XR70CX |
Power supply |
12, 24Vac/dc, 24,110Vac,230Vac 9 - 40Vdc |
24,110Vac, 230Vac |
24,110Vac, 230Vac |
12Vac/dc |
24,110Vac, 230Vac |
12Vac/dc |
Display : number digits |
± 3 d.p. |
± 3 d.p. |
± 3 d.p. |
± 3 d.p. |
± 3 d.p. |
± 3 d.p. |
Probe inputs |
Thermostat |
NTC / PTC |
NTC / PTC |
NTC / PTC |
NTC / PTC |
NTC / PTC |
NTC / PTC |
Thermostat 2 |
- |
- |
- |
- |
- |
- |
Defrost |
NTC / PTC |
NTC / PTC |
NTC / PTC |
NTC / PTC |
NTC / PTC |
NTC / PTC |
Defrost 2 |
- |
- |
NTC / PTC |
NTC / PTC |
- |
- |
Condenser |
NTC / PTCÂ on hot key |
Digital input |
Alarm,start defrost, AUX, door switch, pressure switch, probe |
Configurable |
Configurable |
Configurable |
Configurable |
Configurable |
Configurable |
Alarm,start defrost, AUX, door switch, pressure switch |
- |
- |
- |
- |
- |
- |
Relay outputs |
Compressor |
 8A/16A |
 20A |
 8A/16A |
 16A |
8A/16A |
 16A |
Compressor 2, |
- |
- |
- |
- |
- |
- |
Thermostat 2 |
- |
- |
- |
- |
- |
- |
Defrost |
8A |
8A |
8A |
16A |
8A |
16A |
Defrost 2 |
- |
- |
8A |
16A |
- |
- |
Fan |
8A |
5A |
5A |
16A |
5A |
16A |
Light or Alarm |
- |
- |
- |
- |
8A |
16A |
Anti - sweat |
- |
- |
- |
- |
- |
- |
Other |
Hot key / Programming Tool Kit output |
Present |
Present |
Present |
Present |
Present |
Present |
Remote display output |
X - REP option |
Serial output |
 TTL |
TTL |
TTL |
TTL |
TTL |
TTL |
Buzzer |
available only with compressor = 8A |
Real time clock |
- |
- |
- |
- |
option |
option |
|
Â
FEATURES |
 XR71CX |
XR72CX |
 XR75CX |
 XR77CX |
Power supply |
24, 110Vac, 230Vac |
 12Vac/dc  |
24, 110Vac, 230Vac |
 12Vac/dc  |
24, 110Vac, 230Vac |
 230Vac |
Display : number digits |
± 3 d.p. |
± 3 d.p. |
± 3 d.p. |
± 3 d.p. |
± 3 d.p. |
± 3 d.p. |
Probe inputs |
Thermostat |
 NTC / PTC |
NTC / PTC |
  NTC / PTC |
 NTC / PTC |
NTC / Pt1000 |
NTC / PTC |
Thermostat 2 |
- |
- |
- |
- |
- |
- |
Defrost |
NTC / PTC |
NTC / PTC |
NTC / PTC |
NTC / PTC |
NTC / Pt1000 |
NTC / PTC |
Defrost 2 |
- |
- |
- |
- |
- |
- |
Condenser |
NTC / PTCÂ on hot key |
NTC / Pt1000 |
NTC / PTC |
Digital input |
Alarm,start defrost, AUX, door switch, pressure switch, probe |
 Configurable |
 Configurable |
 Configurable |
 Configurable |
Configurable |
Configurable |
Alarm,start defrost, AUX, door switch, pressure switch |
- |
- |
- |
- |
Configurable |
Configurable |
Relay outputs |
Compressor |
8A/16A |
 16A |
8A/16A |
16A |
8A/16A |
16A |
Compressor 2, Thermostat 2 |
- |
- |
8A |
16A |
- |
- |
Defrost |
8A |
16A |
8A |
16A |
8A |
8A |
Defrost 2 |
- |
- |
- |
- |
- |
- |
Fan |
5A |
16A |
5A |
16A |
5A |
5A |
Light or Alarm |
- |
- |
- |
- |
8A |
8A |
Anti - sweat |
8A |
16A |
- |
- |
- |
- |
Other |
Hot key / Programming Tool Kit output |
Present |
Present |
Present |
Present |
Present |
Present |
Remote display output |
X - REP option |
Serial output |
TTL |
TTL |
TTL |
TTL |
RS485 |
RS485 |
Buzzer |
available only with compressor = 8A |
Real time clock |
- |
- |
- |
- |
option |
 Present |
|
Â
Â
A |
B |
C |
D |
E |
Power Supply |
Inputs |
- |
Buzzer |
X-REP (excludes TTL output) |
RS485Â output |
- |
 Measurement      unit |
RTC |
- |
Compressor output |
Connection |
0Â = 12Vac/dc |
PÂ = PTC |
0 |
No |
No |
No |
C |
°C |
No |
0 |
8A |
Screw |
1Â = 12Vac/dc |
NÂ = NTC |
1 |
Yes |
No |
No |
F |
°F |
No |
1 |
20A |
Screw |
2Â = 24Vdc |
SÂ =Pt1000 Â Â only for XR35/75CX |
2 |
No |
Yes |
No |
H Â |
°C heating only for  XR10CX |
No |
3 |
16A |
Screw |
3 = 9 ÷40Vdc |
3 |
Yes |
Yes |
No |
6 |
8A |
Faston |
4Â = 110Vac |
- - - - |
4 |
No |
No |
Yes |
L |
°F heating only for  XR10CX |
No |
7 |
20A |
Faston |
5Â = 230Vac |
5 |
Yes |
No |
Yes |
8 |
16A |
Faston |
- - |
6 |
No |
Yes |
Yes |
I |
°C |
Yes |
- - |
- - |
- - |
7 |
Yes |
Yes |
Yes |
M |
°F |
Yes  |
|
|
Â
Thermometer Series
Thermometers include bimetallic thermometers, pressure thermometers and marine thermometers, which are suitable for detecting and controlling the liquid level of containers in shipbuilding and other industries.Bimetallic thermometer is a field detection instrument for measuring medium and low temperature. It can directly measure the temperature of liquid steam and gas medium in the range of - 80 ℃ - + 500 ℃ in various production processes. The main element of industrial bimetallic thermometer is a multilayer metal sheet composed of two or more metal sheets, which works based on the principle that two different metals have different expansion degrees when the temperature changes. It is composed of a bimetallic sheet wound into a circular bending shape. When one end is heated and expanded, the pointer is driven to rotate, and the working instrument will display the temperature value corresponding to the thermal potential.
Pressure Type Thermometer,Metalic Protector Thermometer,Flange Bimetallic Thermometer,Glass Tube Industrial Thermometer
Taizhou Jiabo Instrument Technology Co., Ltd. , https://www.taizhoujbcbyq.com