It is used for supervising and controlling return circuit and protective circuit of A.C rated voltage of 450/750V or lower.
Executive standard: GB9332-88
Working Condition
1: Long term working temperature of conductor allowed by cable is 70ºC.
2: Environment temperature for installation is no less than 0ºC.
Min. bending radius of cable is no less than 6 times that of cable OD for cable without armoring, 12 times for
cable with armoring or metallic tape shielding and 6 times for soft cable with shielding structure.
Type, Description and Application Occasion
Â
Product basic information: | ||
Model | Product description | Application fields |
KVV | Cu core, PVC insulator, PVC sheath, control cable | For laying indoors, in cable trench/ ducts and underground. fixed installation |
KVVP | Cu core, PVC insulator, copper wires shielding braid, PVC sheath, control cable | For laying indoors, in cable trench/ ducts and underground, fixed installation. Able to resist interference |
KVVP2 | Cu core, PVC insulator, copper tape shielding braid, PVC sheath, control cable | For laying indoors, in cable trench/ducts and underground, fixed installation. Able to resist interference |
KVVP2-22 | Cu core, PVC insulator, copper tape shielding braid, PVC inner sheath, steel tape armor, PVC outer sheath, control cable | For laying indoors, in cable trench, in ducts. Able to resist interference and bear external mechnical force |
KVV22 | Cu core, PVC insulator, PVC inner sheath, steel tape armor, PVC outer sheath, control cable | For laying indoors, in cable trench/ducts and underground, fixed installation. Able to bear external mechnical force |
KVV32 | Cu core, PVC insulator, PVC inner sheath, steel wires armor, PVC outer sheath, control cable | For laying indoors, in cable trench/ ducts/ inclined lane and underground, fixed installation. Able to bear certain pull |
KVVR | Cu core, PVC insulator, PVC sheath, flexible control cable | For laying indoors, movable and flexible occasion |
KVVRP | Cu core, PVC insulator, copper wires shielding braid, PVC sheath, flexible control cable | For laying indoors, in cable trench, in ducts and underground, movable and flexible occasion. Able to resist interference |
Note: 1: We also produce flame retardant cable according to the requirements of customer. Prefi x "ZR-" should be added. Eg: ZR-KVV type
     2: We also produce cable which does not belong to standard type according to the requirement of customer. Eg. KVVP2-22,KVVP32.
Various Specifi cation Range
Type | Rated voltage V |
Nominal cross section of conductor area | |||||||
0.5 | 0.75 | 1.0 | 1.5 | 2.5 | 4 | 6 | 10 | ||
core number | |||||||||
KVV KVVP |
450/750 | -- | 2-61 | 2-14 | 2-10 | ||||
KVVP2 | -- | 4-61 | 4-14 | 4-10 | |||||
KVV22 | -- | 7-61 | 4-61 | 4-14 | 4-10 | ||||
KVV32 | -- | 19-61 | 7-61 | 4-14 | 4-10 | ||||
KVVR | 4-61 | -- | -- | -- | |||||
KVVRP | 4-61 | 4-48 | -- | -- | -- |
Note: Cores recommended: 2,3,4,5,7,8,10,12,14,16,19,24,27,30,37,44,48,52 or 61.
KVV type control cable with Cu core, PVC insulation and sheath

KVVP type control cable with Cu core, PVC insulation and sheath, braided shielding

KVVP2 type control cable with Cu core, PVC insulation and sheath, copper tape shielding

KVV22 type control cable with Cu core, PVC insulation and sheath, steel tape armoring

Â
 It is used for supervising and controlling return circuit and protective circuit of A.C rated voltage of 450/750V or lower.
Executive standard: GB9332-88
Working Condition
1: Long term working temperature of conductor allowed by cable is 70ºC.
2: Environment temperature for installation is no less than 0ºC.
Min. bending radius of cable is no less than 6 times that of cable OD for cable without armoring, 12 times for
cable with armoring or metallic tape shielding and 6 times for soft cable with shielding structure.
Type, Description and Application Occasion
Â
Product basic information: | ||
Model | Product description | Application fields |
KVV | Cu core, PVC insulator, PVC sheath, control cable | For laying indoors, in cable trench/ ducts and underground. fixed installation |
KVVP | Cu core, PVC insulator, copper wires shielding braid, PVC sheath, control cable | For laying indoors, in cable trench/ ducts and underground, fixed installation. Able to resist interference |
KVVP2 | Cu core, PVC insulator, copper tape shielding braid, PVC sheath, control cable | For laying indoors, in cable trench/ducts and underground, fixed installation. Able to resist interference |
KVVP2-22 | Cu core, PVC insulator, copper tape shielding braid, PVC inner sheath, steel tape armor, PVC outer sheath, control cable | For laying indoors, in cable trench, in ducts. Able to resist interference and bear external mechnical force |
KVV22 | Cu core, PVC insulator, PVC inner sheath, steel tape armor, PVC outer sheath, control cable | For laying indoors, in cable trench/ducts and underground, fixed installation. Able to bear external mechnical force |
KVV32 | Cu core, PVC insulator, PVC inner sheath, steel wires armor, PVC outer sheath, control cable | For laying indoors, in cable trench/ ducts/ inclined lane and underground, fixed installation. Able to bear certain pull |
KVVR | Cu core, PVC insulator, PVC sheath, flexible control cable | For laying indoors, movable and flexible occasion |
KVVRP | Cu core, PVC insulator, copper wires shielding braid, PVC sheath, flexible control cable | For laying indoors, in cable trench, in ducts and underground, movable and flexible occasion. Able to resist interference |
Note: 1: We also produce flame retardant cable according to the requirements of customer. Prefi x "ZR-" should be added. Eg: ZR-KVV type
     2: We also produce cable which does not belong to standard type according to the requirement of customer. Eg. KVVP2-22,KVVP32.
Various Specifi cation Range
Type | Rated voltage V |
Nominal cross section of conductor area | |||||||
0.5 | 0.75 | 1.0 | 1.5 | 2.5 | 4 | 6 | 10 | ||
core number | |||||||||
KVV KVVP |
450/750 | -- | 2-61 | 2-14 | 2-10 | ||||
KVVP2 | -- | 4-61 | 4-14 | 4-10 | |||||
KVV22 | -- | 7-61 | 4-61 | 4-14 | 4-10 | ||||
KVV32 | -- | 19-61 | 7-61 | 4-14 | 4-10 | ||||
KVVR | 4-61 | -- | -- | -- | |||||
KVVRP | 4-61 | 4-48 | -- | -- | -- |
Note: Cores recommended: 2,3,4,5,7,8,10,12,14,16,19,24,27,30,37,44,48,52 or 61.
KVV type control cable with Cu core, PVC insulation and sheath

KVVP type control cable with Cu core, PVC insulation and sheath, braided shielding

KVVP2 type control cable with Cu core, PVC insulation and sheath, copper tape shielding

KVV22 type control cable with Cu core, PVC insulation and sheath, steel tape armoring

Â
LED Fog Light:
1: Each bulb has high power 3030 LED chips. Replacement of the original design of halogen bulb.
2: Easy to install, plug and play, non-polarity. Please notice, for most vehicles, just directly plug and play, yet for some vehicles it may require to install the decoder to avoid the error code or flickering issues, the bulbs are without CANBUS ERROR FREE.
3: Fit: H11, H8, H16 fog light bulb or DRL(Daytime Running Light) ONLY. These bulbs are not headlight bulbs, no high/low beam function. Please make sure the correct size before purchase.
4. LED Brake Bulbs can be used in extreme weather, like cold weather, sizzler and so on. More stable than halogen fog bulb.
LED Fog Light
LED Fog Light,Car LED Light,LED Car Fog Light,Car Driving Light
Huizhou Youtech Light Industrail Co., LTD. , http://www.youtechlight.com