Upgrades include
• Minimum detection limits down to 0.5 ppb
• Negligible temperature response
• Minimal humidity response
• Integral shielding
• Reduced dead volume
• Reduced and improved response time
• Lower pricing
Intrinsically safe design and 4P platform make installation in
portable or stationary gas monitors a snap.
Â
Features and Benefits
• Intrinsically safe
• Saves time and money in R&D and product design
• 4P cell platform compatible
• Variety of ranges and lamp energies
• Quick start lamp ignition circuit
• Long lamp life
• Input voltage regulation for greater stability
• Easily cleaned and field serviced
• Out of warranty Sensor Exchange Program
Â
10.6eV
Green
Purple
Red
Yellow
Blue
Part Number
045-010
045-011
045-012
045-013
045-014
Range *
10,000 ppm
2,000 ppm
200 ppm
20 ppm
2 ppm
MDQ *
500 ppb
100 ppb
10 ppb
1.5 ppb
0.5 ppb
T90 response Factor
≤ 2 sec (typical)
≤ 2 sec (typical)
≤ 2 sec (typical)
≤ 4 sec (typical)
≤ 4 sec (typical)
Applications
• Industrial Hygiene & Safety Monitoring
• Confined Space Entry
• Soil Contamination and Remediation
• Hazmat Sites & Spills
• Low Concentration Leak Detection
• Indoor Air Quality
• EPA Method 21
Â
Physical Characteristics All sensors calibrated with Isobutylene
Complete sensing unit includes detector cell, UV lamp, lamp driver, amplifier and sample filter
Weight
< 8 gr
Package Type
4P cell dimensional profile
Serviceable Parts
lamp, detector cell, filters (2), cap, spacer
Lamp Life
Guaranteed 6000 hours - Typical life significantly longer
Onboard Filters
Removes liquids / particles
Warranty Period
1st of 18 months from ship date or 12 months from install date
Electrical Characteristics
Supply Voltage
3.2V-5.5V (input voltage regulator included)
Current
24mA - 36mA
Power Consumption
80 mW - 200 mW - Dependent upon supply voltage
Output Signal
0.045V - 2.5V
Operating Conditions
Temperature Range
-20o C to 60ºC (-4o F to 104ºF)
Relative Humidity Range
0 to 90% non-condensing
Humidity Response
< 1 % @ 90% relative humidity
Humidity Quenching Effect
< 15% @ 90% relative humidity
Accuracy
±3% of reading, with constant temperature and pressure
Certifications & Approvals*
piD-TECH eVx is a UL certified component. Intrinsically safe - no external components required.
USA
UL 913 (Eighth Edition), For use in Class I, Division 1, Groups A, B, C, D Locations.
Europe
ATEX directives: EN 60079-0:2012, A11:2013; EN 60079-11:2012, Ex II 1 G Ex ia IIC Ga T4, Tamb = -20C to +60C
ATEX Certificates: DEMKO 13 ATEX 1304446U Rev.1; CE 0539
Other
IECEx Standards:60079-0 Ed.6; 60079-11, Ed6; Certificate IECEx UL 13.0050U Issue:1; CAN/CSA C22.2 No. 157-92
Patents
US Pat 6,646,444, Japan Pat 3,793,757
Mechanical Specifications
Â
PID Detector Sensor 200 ppm Alarm Photoionization Detector Voc Tvoc Leak Contamination Detection MDQ 10 ppb
Model NO.: PID/0-200
Sensitivity: High
Certification: RoHS
Customized: Customized
Trademark: Baseline Mocon
Transport Package: Factory Sealed
Specification: 20.4*17.6(+4.78)
Origin: United States
HS Code: 9027100090