±4KV ESD test for Bluetooth headsets

First, the description before the rectification:

Two separate Bluetooth headsets, wirelessly connected between the two headsets, and then the left ear is connected to the playback device via Bluetooth. When performing the ESD test of ±4KV, it is found that the Bluetooth headset will restart, or the Bluetooth status cannot be connected. This is not in accordance with the standard Class B of IEC61000-4-2. The following figure is the test point:

±4KV ESD test for Bluetooth headsets

Second, the rectification process:

The red icon in the above figure is the electrostatic test point, because this is two bare metal dots, one of which is GND and one is 5V. After repeated testing, this product will appeal when it is ±3KV. Disassemble the product and observe its internal structure. It is found that the antennas below the two test points are Bluetooth antennas. The antenna and the PCB board are connected by electric shock. Therefore, first we take the antenna out. When testing, we found that the product has improved. Hit to 3.5KV or so). Confirm that the antenna has some interference to the ESD. We connect an ASIM ESD in parallel with the ground on the antenna (model: ESD5D003TA, the junction capacitance of this ESD is 0.3pF, which has no effect on the performance of the antenna). When testing, it is found that the product can accept 3.5KV static test; but still unstable at 4KV.

Then the ESD test point is processed. The ASIM ESD (model: ESD5D150TA) is connected in parallel to the ground at 5V and a magnetic bead is placed on the 5V, and a large capacitor is connected in parallel to the ground. When testing, it was found that the product can accept ±4KV ESD test, which is in line with IEC61000-4-2 Class B standard. It has been confirmed that the product has received ±5KV ESD test.

Third, summary:

The cause of ESD interference is not only related to the PCB board, but also has a great relationship with the structure of the product. When performing ESD rectification, it is first to find out which module the product is interfered with. The right medicine is a shortcut for ESD rectification.

Wall Mounted Battery Pack

Wall Mounted Battery,Wall-Mounted Lithium-Ion Battery,Residential Wall-Mount Battery,Wall Mounted Lithium Battery

JIANGMEN RONDA LITHIUM BATTERY CO., LTD. , https://www.ronda-battery.com