Introduction IKS-6726 industrial-grade rack switches are designed for industrial applications, such as traffic control systems (NEMA TS2) and maritime applications (DNV / GL). IKS-6726 supports Gigabit and Fast Ethernet backbone networks, redundant ring networks and isolated two power inputs (24/48 VDC or 110/220 VDC / VAC), which can improve communication stability and save wiring costs. IKS-6726 adopts modular design, network planning and configuration is more flexible, up to 2 Gigabit Ethernet ports and 24 Fast Ethernet ports can be installed.
Features-Support Turbo Ring and RSTP / STP (IEEE 802.1w / D)
-Support IGMP snooping and GMRP for multicast filtering
-Support IEEE 802.1Q VLAN and GVRP for easy network planning
-Support QoS-IEEE 802.1p / 1Q and TOS / DiffServ, increase network certainty
-Support 802.3ad, LACP, optimize network bandwidth
-Support IEEE 802.1X, HTTPS and SSH to increase network security
-Support SNMPv1 / v2 / v3 network management protocols of different levels
-Support RMON to effectively monitor the network
-Support ABC-01 for quick backup of system configuration
-Support bandwidth management to prevent unforeseen network failure
-Support port locking based on MAC address to prevent illegal intrusion
-Support port mirroring function for easy online debugging
-Automatically report unexpected events via e-mail and relay output
-Automatically restore the IP address of the connected device
-Quickly restore circuit switching
-Configurable via web browser, Telnet / Serial Console, Windows tools and ABC-01

Technical standard: IEEE 802.3 applies to 10BaseT,
IEEE 802.3u is suitable for 100BaseT (X) and 100Base FX,
IEEE 802.3z is suitable for 1000BaseSX / LX / LHX / ZX,
IEEE 802.3x is suitable for flow control,
IEEE 802.1D is suitable for SPT spanning tree protocol,
IEEE 802.1w is suitable for RSTP rapid spanning tree protocol,
IEEE 802.1Q is suitable for VLAN Tagging,
IEEE 802.1p is applicable to Class of Service,
IEEE 802.1X is suitable for authentication,
IEEE 802.3ad is suitable for LACP-based port aggregation protocols: IGMPv1 / v2 device, GMRP, GVRP, SNMPv1 / v2c /
v3, DHCP Server / Client, DHCP OpTIon 82, BootP, TFTP,
SNTP, SMTP, RARP, RMON, HTTP, HTTPS, Telnet, SSH,
Syslog
MIB: MIB-II, Ethernet-Like MIB, P-BRIDGE MIB,
Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB
Group 1, 2, 3, 9
Flow control: IEEE 802.3x flow control, backplane pressure flow control

Switch Attribute Priority: 4
Maximum number of available VLANs: 64
VLAN ID range: VID 1 to 4094
IGMP Groups: 256

Interface Fast Ethernet port: Slot 1 and slot 2 are suitable for installing PM-7200 series
Fast Ethernet module with 8/7/6 ports (10/100 BaseT (X) or 100
BaseFX (SC / ST connector))
Gigabit Ethernet port: Slot 3 is suitable for installing PM-7200 series 2-port composite module (10/100 / 1000BaseT (X) or 1000BaseSFP slot)
Console: RS-232 (RJ45)
System LED indicators: STAT, PWR1, PWR2, FAULT, MASTER,
COUPLER
Module LED indicators: LNK / ACT, FDX / HDX, RING PROT,
COUPLER PROT, SPEED
Alarm contact: 1 relay output, current load capacity 3A @ 30 VDC or
3A @ 240 VAC

Power requirements Input voltage: 24 VDC (18 ~ 36 V), or 48 VDC (36 ~ 72 V), or
110/220 VDC / VAC (88 ~ 300 VDC and 85 ~ 264 VAC)
Connection method: 10-pin terminal block wiring overcurrent protection: with reverse connection protection: yes

Physical characteristics Case: IP30 protection size (W x H x D): 440 x 44 x 325mm
(17.32 x 1.73 x 12.80 in.)
Installation method: 19 "rack installation

Environmental parameters Operating temperature: -40 ~ 75 ° C (-40 ~ 167 ° F)
Cold start minimum voltage 100 VAC at -40 ° C
Storage temperature: -40 ~ 85 ° C (-40 ~ 185 ° F)
Working humidity: 5 ~ 95% (no condensation)

Safety certification Safety: EN60950-1 (in application)
Maritime certification: DNV (in application), GL (in application)
Transportation certification: NEMA TS2
EMI: FCC Part 15, CISPR (EN 55022) class A
* Please visit Moxa website for the latest certification information

warranty period
5 years

Available models
Product Number Description IKS-6726-F-24 Modular network-managed Ethernet switch, 8 10 / 100BaseT (X) interfaces, 2-slot Fast Ethernet module, 1-slot Gigabit Ethernet module, up to 24 + 2G interfaces , Front panel outlet, 1 isolated power supply (24 VDC), -40 ~ 75 ° C
IKS-6726-F-24-24 Modular network management type Ethernet switch, 8 10 / 100BaseT (X) interfaces, 2 slots fast Ethernet module, 1 slot Gigabit Ethernet module, up to 24 + 2G interface, Front panel outlet, 2 isolated power supplies (24 VDC), -40 ~ 75 ° C
IKS-6726-F-24-48 Modular network management type Ethernet switch, 8 10 / 100BaseT (X) interfaces, 2 slots fast Ethernet module, 1 slot Gigabit Ethernet module, up to 24 + 2G interface, Front panel outlet, 2 isolated power supplies (24 and 48 VDC), -40 ~ 75 ° C
IKS-6726-F-24-HV Modular network management Ethernet switch, 8 10 / 100BaseT (X) interfaces, 2 slots Fast Ethernet module, 1 slot Gigabit Ethernet module, up to 24 + 2G interface, Front panel outlet, 2 isolated power sources (24 VDC and 88-300 VDC or 85-264 VAC), -40 ~ 75 ° C
IKS-6726-F-48 Modular network-managed Ethernet switch, 8 10 / 100BaseT (X) interfaces, 2-slot Fast Ethernet module, 1-slot Gigabit Ethernet module, up to 24 + 2G interface, front panel Outgoing line, 1 isolated power supply (48 VDC), -40 ~ 75 ° C
IKS-6726-F-48-48 Modular network management type Ethernet switch, 8 10 / 100BaseT (X) interfaces, 2 slots fast Ethernet module, 1 slot Gigabit Ethernet module, up to 24 + 2G interface, Front panel outlet, 2 isolated power supplies (48 VDC), -40 ~ 75 ° C
IKS-6726-F-48-HV Modular network management type Ethernet switch, 8 10 / 100BaseT (X) interfaces, 2 slots fast Ethernet module, 1 slot Gigabit Ethernet module, up to 24 + 2G interface, Front panel outlet, 2 isolated power supplies (48 VDC and 88-300 VDC or 85-264 VAC), -40 ~ 75 ° C
IKS-6726-F-HV Modular network-managed Ethernet switch, 8 10 / 100BaseT (X) interfaces, 2-slot Fast Ethernet module, 1-slot Gigabit Ethernet module, up to 24 + 2G interface, front panel Outgoing line, 1 isolated power supply (88-300 VDC or 85-264 VAC), -40 ~ 75 ° C
IKS-6726-F-HV-HV Modular network management type Ethernet switch, 8 10 / 100BaseT (X) interfaces, 2 slots fast Ethernet module, 1 slot Gigabit Ethernet module, up to 24 + 2G interface, Front panel outlet, 2 isolated power supplies (88-300 VDC or 85-264 VAC), -40 ~ 75 ° C
OPC server software
Product number description EDS SNMP-OPC server CD with EDS-SNMP OPC server software and manual
SFP-1G module
Product number description SFP-1GSXLC SFP module, 1 1000BaseSX interface, LC connector, 0.5 km distance transmission, 0 ~ 60 ° C
SFP-1GLSXLC SFP module, one 1000BaseSX interface, LC connector, 0.5 km distance transmission, 0 ~ 60 ° C
SFP-1GLXLC SFP module, one 1000BaseLX interface, LC connector, 10 km distance transmission, 0 ~ 60 ° C
SFP-1GLHXLC SFP module, one 1000BaseLHX interface, LC connector, 40 km distance transmission, 0 ~ 60 ° C
SFP-1GZXLC SFP module, one 1000BaseZX interface, LC connector, 80 km distance transmission, 0 ~ 60 ° C
SFP-1GEZXLC SFP module, one 1000BaseZX interface, LC connector, 110km distance transmission, 0 ~ 60 ° C
SFP-1G10ALC WDM-type (BiDi) SFP module, one 1000BaseSFP interface, LC connector, 10 km distance transmission, TX 1310 nm, RX 1550 nm, 0 ~ 60 ° C
SFP-1G10BLC WDM-type (BiDi) SFP module, one 1000BaseSFP interface, LC connector, 10 km distance transmission, TX 1550 nm, RX 1310 nm, 0 ~ 60 ° C
SFP-1G20ALC WDM-type (BiDi) SFP module, one 1000BaseSFP interface, LC connector, 20 km distance transmission, TX 1310 nm, RX 1550 nm, 0 ~ 60 ° C
SFP-1G20BLC WDM-type (BiDi) SFP module, one 1000BaseSFP interface, LC connector, 20 km distance transmission, TX 1550 nm, RX 1310 nm, 0 ~ 60 ° C
SFP-1G40ALC WDM-type (BiDi) SFP module, one 1000BaseSFP interface, LC connector, 40 km distance transmission, TX 1310 nm, RX 1550 nm, 0 ~ 60 ° C
SFP-1G40BLC WDM-type (BiDi) SFP module, one 1000BaseSFP interface, LC connector, 40 km distance transmission, TX 1550 nm, RX 1310 nm, 0 ~ 60 ° C
SFP-1GSXLC-T SFP module, one 1000BaseSX interface, LC connector, 0.5 km distance transmission, -20 ~ 75 ° C
SFP-1GLSXLC-T SFP module, one 1000BaseSX interface, LC connector, 0.5 km distance transmission, -20 ~ 75 ° C
SFP-1GLXLC-T SFP module, one 1000BaseLX interface, LC connector, 10 km distance transmission, -40 ~ 85 ° C
SFP-1GLHXLC-T SFP module, one 1000BaseLHX interface, LC connector, 40 km distance transmission, -40 ~ 85 ° C
SFP-1GZXLC-T SFP module, one 1000BaseZX interface, LC connector, 80 km distance transmission, -40 ~ 85 ° C
SFP-1G10ALC-T WDM-type (BiDi) SFP module, one 1000BaseSFP interface, LC connector, 10 km distance transmission, TX 1310 nm, RX 1550 nm, -40 ~ 85 ° C
SFP-1G10BLC-T WDM-type (BiDi) SFP module, one 1000BaseSFP interface, LC connector, 10 km distance transmission, TX 1550 nm, RX 1310 nm, -40 ~ 85 ° C
SFP-1G20ALC-T WDM-type (BiDi) SFP module, one 1000BaseSFP interface, LC connector, 20 km distance transmission, TX 1310 nm, RX 1550 nm, -40 ~ 85 ° C
SFP-1G20BLC-T WDM-type (BiDi) SFP module, 1 1000BaseSFP interface, LC connector, 20 km distance transmission, TX 1550 nm, RX 1310 nm, -40 ~ 85 ° C
SFP-1G40ALC-T WDM-type (BiDi) SFP module, one 1000BaseSFP interface, LC connector, 40 km distance transmission, TX 1310 nm, RX 1550 nm, -40 ~ 85 ° C
SFP-1G40BLC-T WDM-type (BiDi) SFP module, one 1000BaseSFP interface, LC connector, 40 km distance transmission, TX 1550 nm, RX 1310 nm, -40 ~ 85 ° C
PM-7200 series interface module
Product number description PM-7200-2GTXSFP Gigabit Ethernet switch module, 2 10/100 / 1000BaseT (X) or 1000BaseSFP slot composite ports
PM-7200-1LSC6TX Fast Ethernet module, 1 single-mode 100BaseFX interface, SC connector, 80 km transmission distance, 6 10 / 100BaseT (X) interfaces PM-7200-2MST4TX Fast Ethernet module, 2 multimode 100BaseFX interfaces , ST connector, 4 10 / 100BaseT (X) interfaces PM-7200-2MSC4TX fast Ethernet module, 2 multimode 100BaseFX interfaces, SC connectors, 4 10 / 100BaseT (X) interfaces PM-7200-2SSC4TX fast Ethernet Module, 2 single-mode 100BaseFX interfaces, SC connectors, 4 10 / 100BaseT (X) interfaces PM-7200-4MST2TX Fast Ethernet module, 4 multimode 100BaseFX interfaces, ST connectors, 2 10 / 100BaseT (X) interfaces PM-7200-4SSC2TX Fast Ethernet module, 4 single-mode 100BaseFX interfaces, SC connectors, 2 10 / 100BaseT (X) interfaces PM-7200-6MST Fast Ethernet module, 6 multimode 100BaseFX interfaces, ST connectors PM- 7200-6MSC Fast Ethernet module, 6 multimode 100BaseFX interfaces, SC connector PM-7200-6SSC Fast Ethernet module, 6 single-mode 100BaseFX interfaces, SC connector PM-7200-8TX Fast Ethernet module, 8 10 / 100BaseT (X) interface

Coupletech Co., Ltd also supplies water cooled modules, air cooled modules and heat-sink system for high power laser. Usually we need to use all kinds of methods, e.g. water cooling, air cooling and heat sink to make the Laser Crystal, nonlinear crystal and Pockels Cell work normally within specified operating temperature range. Thus we need crystal mounts with water cooling, air cooling or heat sinking.

air cooling and water cooling modules

water cooled modules

Accessories

Narrow Aluminium Optical Rail,Narrow Aluminium Rail Carriers,Aluminium Optical Rails